Deutsch
|
English

Rooms

Support Center

IC10780

Navigation to this function

This evaluation provides an overview of the types of use of the rooms (type of use according to DIN 277-2).


search

This group contains features for searching and filtering rooms. It enables users to quickly find and select specific rooms based on various criteria.
PropertyDescription
Traffic lightRed: There is an area without a type of use | Yellow: There is an area with type of use 0.0 (not according to DIN 277). | Green: All areas have a type of use according to DIN 277.
NoteThe note in this column gives you further information on the displayed traffic light color. Follow the instructions to be able to change red and yellow traffic lights in particular.
Room CodeSpecification of the room code with link to the room.
TypeSpecification of the type of use (NF: utilization area, TF: technical area, VF: traffic area).
CodeSpecification of the usage type code.
NF 1 [m²]Specification of the area with types of use 1.x in m².
NF 2 [m²]Specification of the area with types of use 2.x in m².
NF 3 [m²]Specification of the area with types of use 3.x in m².
NF 4 [m²]Specification of the area with types of use 4.x in m².
NF 5 [m²]Specification of the area with types of use 5.x in m².
ClientThe logical client is visible at this point. This is always 01 as long as the client separation has not been activated. Please refer to the help.
NF 6 [m²]Specification of the area with types of use 6.x in m².
NF 7 [m²]Specification of the area with types of use 7.x in m².
NF ∑ [m²]Indication of the total usable area (types of use 1.x to 7.x) in m².
NF NumberIndication of the number of assigned land use types for this area.
TF 8 [m²]Specification of the area with types of use 8.x (technical areas) in m².
VF 9 [m²]Specification of the area with types of use 9.x (traffic areas) in m².
TF QuantitySpecification of the number of assigned types of technical surfaces for this room.
VF QuantityIndication of the number of assigned traffic area types for this space.
none [m²]Specification of the area without type of use in m².
no numberIndication of the number of areas without type of use in this room.
Quantity no area according to DINSpecification of the number of areas with usage type 0.0 (not in accordance with DIN 277).
NF 0 [m²]Specification of the area with usage type 0.0 (not according to DIN 277) in m².
GFA [m²]Indication of the total area except type of use 0.0 in m².
NGF NumberIndication of the total number of recorded areas.
Building life cycle phaseIndication of the life cycle phase of the building.

Excel export

This group contains features that are relevant for exporting spatial data to Excel tables. It includes properties that enable a structured presentation and analysis of spatial information in tabular form.
PropertyDescription
Location codeSpecification of the location code.
Floor codeSpecification of the floor code.
Building codeSpecification of the building code.
War dieser Artikel hilfreich?